| Overall rating | (2 reviews) |
For indoor installations, the maximum length of the LPG hose is 1.2 meters.
The inner diameter must be 10 mm (VNa 858/2012 Annex, Sections 4 and 6). There is no mention of the length and inner diameter of the LPG hose in relation to outdoor spaces. The procedure in accordance with so-called good practice is to use hose lengths that are necessary for use and to avoid using hoses that are too long. There are many different types of awnings. A clear view can be taken that from the point of view of using LPG, a so-called awning solution (only the top is closed and otherwise all sides are open) can be considered outdoor space. A full-length Caravan awning is inconvenient from the point of view of using LPG. The provision concerning the placement of operating devices (VNa 858/2012 Annex, Sections 2 and 3) is based on the location of the installation. Section 2 deals with the rooms of buildings, so it is not applicable here. Section 3 requires: Operating devices must have a flame monitoring device. A flame monitoring device is not required for appliances intended exclusively for controlled outdoor use. This can therefore be applied to this LPG grill for Caravan use.
| Overall rating | ☆☆☆☆☆ |
— Show original